How-To Guide
How to Clean and Store a Nebulizer Machine
How to clean nebulizer machine parts after each use, disinfect at home, dry the air tube and store everything, based on Omron's NE-C28 manual.
To clean a nebulizer machine, discard leftover medicine, then wash the nebulizer kit, mask and mouthpiece in warm water with a mild detergent after every use, rinse in clean hot water, and air dry in a clean place. The Omron NE-C28 manual allows boiling parts 15–20 minutes to disinfect. Never wash the compressor or air filter.
Here is the full clean, disinfect, dry and store routine, taken from the manufacturer's instructions, so your home nebulizer keeps delivering mist cleanly between sessions.
Why should you clean a nebulizer machine after every use
The Omron NE-C28 manual is explicit: clean the parts after each use to remove residual medication, which avoids inefficient nebulization or infection. Dried medicine inside the kit also narrows the nozzle and weakens the mist you inhale.
Public-health bodies such as the World Health Organization and Bangladesh's Ministry of Health and Family Welfare treat home-use medical devices as shared hygiene surfaces, so keeping them clean is basic home care. A clean kit protects the next session as much as this one.
What do you need to clean a nebulizer machine at home
Nothing special, and no harsh chemicals. The manual calls for warm water, a mild (neutral) detergent, clean hot tap water and a clean place to air dry.
- A bowl of warm water with a few drops of mild, neutral detergent.
- Clean hot tap water for the final rinse.
- A soft, clean, lint-free cloth for the compressor casing.
- A clean, covered surface or basket for air drying the parts.
- A dry, sealed bag for storing the nebulizer kit afterwards.
How do you clean a nebulizer machine step by step
Work through these steps straight after each session, while the parts are still easy to rinse. The sequence follows the cleaning section of the Omron NE-C28 instruction manual.
- Switch the compressor off and unplug it from the power outlet first.
- Remove the inhalation accessory — mouthpiece, mask or nosepiece — from the nebulizer kit.
- Disconnect the air tube from the nebulizer kit.
- Gently twist the inhalation top counterclockwise and lift to open the nebulizer into two sections, then remove the baffle.
- Discard any remaining medicine in the medication cup. Never keep it for the next session.
- Rinse the nebulizer kit parts and the mouthpiece or nosepiece with hot tap water. The manual also allows these parts on a dishwasher top rack in a basket — but never the mask.
- Rinse the mask separately with hot tap water.
- Wash the washable parts in warm water with mild detergent, rinse thoroughly with clean hot tap water, and do not leave cleaning solution to dry on them.
- Wash the vaporizer head under running water only, with no brush and no pin.
- Hand dry or air dry the parts on a clean surface in a clean environment, then reassemble and store the kit in a dry, sealed bag.
How do you disinfect a nebulizer machine at home
Washing after every use is the routine. The manual adds deeper disinfection for three moments: the first time after purchase, after the device has not been used for a long period, and whenever more than one person uses the same device.
Two disinfecting methods are described in the manual:
- Boil the applicable nebulizer accessories in plenty of water for 15–20 minutes, then carefully remove them, shake off excess water and air dry in a clean environment. Never let the container boil dry.
- Or use a commercially available disinfectant, following that disinfectant manufacturer's instructions, and rinse the parts with clean hot tap water afterwards.
Never clean with benzene, thinner or any flammable chemical, and never use an autoclave, EOG gas sterilizer or low-temperature plasma sterilizer on the parts.
Which nebulizer parts must never be washed
Two items stay dry. The compressor (main unit) is wiped only, and the air filter is never washed or cleaned at all.
- Compressor: unplug it, then wipe the casing with a soft cloth moistened with water or mild detergent. Do not use abrasive cleaners and never immerse the unit in water or any liquid. Dry the casing immediately with a soft clean cloth.
- Air filter: do not wash it. If the air filter becomes wet, replace it, because a damp filter can cause blockages. Check before each use that the filter is clean and free of dust, and never run the compressor without one.
How do you dry and store a nebulizer machine
Let the washed parts air dry in a clean place, or pat them with a soft, clean, lint-free cloth. The manual rules out a microwave oven, dish dryer and hair dryer for drying, so plan for air drying time after every session.
If moisture remains inside the air tube, the manual gives a quick fix:
- Leave the air tube connected to the air connector on the compressor.
- Remove the air tube from the nebulizer kit.
- Switch the compressor on and pump air through the tube to expel the moisture.
Store the nebulizer kit in its dry, sealed bag with the mouthpiece, mask and tube fully dry, and keep the whole unit away from dust, heat and damp. Do not leave cleaning solution on any part to dry.
How often should you clean and service a nebulizer at home
Wash the parts after every single session. Disinfect on the three occasions the manual lists, and replace the air filter when it has been in use for more than 60 days or the moment it gets wet.
Inspect the vaporizer head, nozzle, air tube and compressor before each session; if anything is damaged or the nozzle is blocked, replace the part before the next use. Genuine replacement filters and kits keep the mist output consistent.
What nebulizer accessories should you keep at home
Keeping spares means a cleaning day never cancels a scheduled session. The Omron Compressor Nebulizer NE-C28, listed in Bikarok's catalogue at ৳6,500, ships with a nebulizer kit, mouthpiece, adult and child masks, air tube and five spare air filters.
- Replacement air filters (never reusable once wet).
- A spare nebulizer kit so one can dry while the other is in use.
- Separate masks for each person in the household.
- A clean, sealed storage bag for the dry kit.
All of these are stocked in Bikarok's nebulizer accessories range, linked at the bottom of this page.
Frequently asked questions
How often should I clean my nebulizer machine?
Clean it after every use, without exception, so residual medicine does not dry inside the kit. The Omron manual says skipping this can lead to inefficient nebulization or infection. Disinfect more deeply before first use, after long storage, or when the device is shared.
Can I wash the nebulizer compressor in water?
No. The compressor must never be immersed in water or any other liquid, as the manual warns. Unplug it and wipe the casing with a soft cloth moistened with water or mild detergent, then dry it immediately with a soft clean cloth.
Can I clean nebulizer parts in a dishwasher?
For the NE-C28, the manual allows the nebulizer kit parts, mouthpiece and nosepiece to be washed in a dishwasher on the top rack in a suitable basket. The mask must not go in a dishwasher and is rinsed by hand with hot tap water. Check your own model's manual before trying this.
How do I remove moisture from the nebulizer air tube?
Keep the tube connected to the compressor, detach its other end from the nebulizer kit, and run the compressor so air is pumped through the tube to expel the moisture. Never wash the air tube and then store it damp, and remember a wet air filter must simply be replaced.
Can I use alcohol or boiling water to disinfect a nebulizer machine?
Boiling is supported: the manual says parts may be boiled for 15–20 minutes in plenty of water, then air dried in a clean environment. Never use benzene, thinner or any flammable chemical. For other disinfectants, follow the disinfectant manufacturer's own instructions and rinse the parts with clean hot tap water.
When should I replace nebulizer accessories?
Replace the air filter after more than 60 days of use, or straight away if it becomes wet. Replace any part the manual asks you to inspect — vaporizer head, nozzle or air tube — when it is damaged, because the instructions require them to be problem-free before each session.
Where to go next on Bikarok
- Nebulizer machine accessories — filters, masks, mouthpieces and replacement kits.
- Omron Compressor Nebulizer NE-C28 — the machine this cleaning routine follows, listed at ৳6,500.